
GA1202CAL Digital Storage 200MHz Oscilloscope Scopemeter 2Channels 1GSas USB 7 TFT LCD AC 110240V
GA1202CAL+ Digital Storage 200MHz Oscilloscope Scopemeter 2Channels 1GSa/s USB 7 TFT LCD AC 110-240V
Use Tutorials Video: * Check
The disadvantage of this test indicates that some models cannot be tested when the resolution of this tester is above 3K. Ltn133yl02 / 03 / 04 / 05 / 06 can not be tested normally, so only self-test line can be used. Other LCDs with resolution above 3K do not promise to test normally. The resolution below 3K is no problem.
1. This EDP tester has intelligent screen parameter configuration function, 6-bit screen uses 01, 8-bit screen uses 02. In general, the screen with 1920 * 1080 resolution and above uses 02, and the screen with 1920 * 1080 resolution and below uses 01. When you don't know the resolution, you can try 02 first. In all EDP screens, about 10% of the screens can not match the intelligent screen parameters, so it is necessary to use the accurate screen parameter number.
2. For the configuration of accurate screen reference number, first search the LCD screen model to be tested in Baidu to determine the screen type and resolution. Then query the corresponding number. Each resolution is divided into 6-digit and 8-digit, with a total of 6 numbers. It is generally recommended to use 8-digit screen reference number first.
3 EDP screen is usually 30 pins with 0.5 spacing. The standard line of the screen tester can measure 80% EDP screen with 1920 * 1080 resolution and below, which is different from LVDS screen. The screen with 2K resolution or above and the screen line with standard configuration can not be tested normally needs to be made by hand, and the LCD screen needs to be provided at the same time. Generally, it is connected to ports a, C and D of the tester. When the screen is bright, but the screen is flashing or black, port B, C and D are used. If some manual lines do not have port C, only port B and D are needed. The standard line of EDP screen whose screen model starts with vvx can't be applied, so it must be done manually again. Au screen containing b116htn, b133htn, b140htn and b156htn can be normally displayed with B, C and D. Qimei's n133hse-ea3 / EB3 can be displayed normally only with B, C and D.
4. If a, C, D or B, C, D glass signal image display is normal but the backlight is not bright, it means that the screen does not have its own backlight boost module, and it needs to do the screen connecting line and external constant current board manually.
No customer reviews for the moment.
GA1202CAL+ Digital Storage 200MHz Oscilloscope Scopemeter 2Channels 1GSa/s USB 7 TFT LCD AC 110-240V
4K Signal Universal T-300 Tester 55 Models Procedures Through All the eDP signal 3840*2160 LCD screen
TV160 Flat Panel TV Brusher Upgrade Box Skyworth Universal Upgrade
Hantek T3100 Oscilloscope Probe Accessories with Alligator Clip 1X 100X 120MHz
Hantek DSO5102P USB Storage Oscilloscope Oszilloskope 2 Channels 100MHz 1GSa/s
ZOTEK ZT-M1 Automatic Manual Digital Large LCD Screen Display AC DC Multimeter
ZOYI ZT-300AB Automatic recognition of Bluetooth with high precision Multimeter
LCD PC Power Supply Tester 20/24 Pin 4 SATA HDD Netzteil Tester Adapter Diagnose
T-V18 Test Tool for Panel Problems LED LCD Screen Tester Support 7-84 LVDS Screen
T-V18 LED LCD Screen Tester Support 7-84+V29V56V59 Universal LCD TV Controller Driver Board
TV160-MiniLVDS-transfer LVDS converter with 6th-7th Generation Easy to Carry - Powerful protection Function
ZOYI ZT-S1 Digital Multimeter Tester Autoranging True Rms Automotriz
1 Pair 1000V 20A Universal Digital Multimeter Multi Meter Test Lead Probe Wire Pen Cable L1Y
ZOTEK ZT-X true rms Digital Multimeter auto range with NCV DATA HOLD LCD Backligh
TV160 LVDS FPC Conversion Link Board for LG CHIMEI Samsung
TV160 LVDS Conversion Link Board for 7th VBY 120Hz 4K 51Pin Dual screen interface input